¡á 2Â÷ÀüÁö(ÃæÀü¿ë) ¡é
¸®Æ¬Æú¸®¸Ó Polymer
¸®Æ¬Æú¸®¸Ó Á¶¸³
¸®Æ¬ÀÌ¿Â Li-ion
¸®Æ¬ÀÌ¿Â Á¶¸³
´ÏÄ«µå, ´ÏÄ̼ö¼Ò
´ÏÄ«µå,´ÏÄ̼ö¼Ò Á¶¸³
ÄÚÀÎ, ¹öÆ° 3V
³³Ãà(¿¬Ãà) PbSO
¸®Æ¬ÀÌ¿Â Äܵ§¼­ ¹èÅ͸® ¿Ü
Àλêö LiFePO4
ÁýÇÕ2Â÷ÀüÁö (Á¶¸³)
¡á 1Â÷ÀüÁö(ÀÏȸ¿ë) ¡é
¸Á°£, ¾ËÄ«¶óÀÎ
»êÈ­Àº, ¡ũ¿¡¾î
¸®Æ¬ 3V (µ¿ÀüÇü)
¸®Æ¬ 1.5V 3V 6V 9V
¸®Æ¬ 3.6V
ÁýÇÕ1Â÷ÀüÁö(Á¶¸³)
¡á ¹èÅ͸® ¿Ü eLse ¡é
ÃæÀü±â Charger
¹èÅ͸®È¦´õ Holder
Ä¿³ØÅÍ Connecter
º¸È£È¸·Î(PCM)
¡Ü µµ¸Å, Àç°í ÇÒÀÎ
¡ß â°í Warehouse
Áú¹®°ú ´äº¯ÀÌ Àִ°÷
µµ¿ò¸»ÀÌ Àִ°÷
¹èÅ͸® ½ºÆÑÀÌ Àִ°÷
 TEL 02-6679-3399

  010-4583-3397

  FAX 02-6679-3396

¿ù~¸ñ 9:30 ~ 17:00
±Ý¿äÀÏ 9:30 ~ 16:00
Á¡ ½É 12:00 ~ 13:00
Åä¿äÀÏ, ÀÏ¿äÀÏ
°øÈÞÀÏÀº ½±´Ï´Ù
gajinbattery@
gmail.com


À̸ÞÀϹ®ÀÇ
½ÅÇÑÀºÇà
140-009-987891
(ÁÖ)°¡Áø¹èÅ͸®
 
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
¸®Æ¬ 3.6V > [ D ] > < »çÇÁÆ® Saft > > Saft LSH20(D 3.6V 13000mAh) High power

 
Saft LSH20(D 3.6V 13000mAh) High power
»çÇÁÆ® LSH20 3.6V °íÃâ·Â ÆÄ¿ö¿ë ¸®Æ¬1Â÷¹èÅ͸®
Á¦Á¶È¸»ç : Saft »çÇÁÆ®
(D) 33.4 x 61.6mm 100g
ÆǸŰ¡°Ý : 50,000¿ø
Àû¸³±Ý¾× : 500¿ø
¼ö·® EA
 
 
     
(µµ¸Å/´ëü»óÇ°)Comf BH111-1A(D1N-A) ÄÞÇÁ BH111A ¹èÅ͸®È¦´õ Saft LSH20-A(D 3.6V 13Ah) High Power »çÇÁÆ® LSH20 3.6V ¸®Æ¬1Â÷¹èÅ͸® °íÃâ·Â ÆÄ¿ö¿ë Saft LSH20-PK(D 3.6V 13000mAh)CHL0640RB High power »çÇÁÆ® LSH20 3.6V ¸®Æ¬1Â÷¹èÅ͸® °íÃâ·Â ÆÄ¿ö¿ë Saft LSH20-SB540-Safe(D 3.6V 13000mAh)
0¿ø 51,000¿ø 51,000¿ø 52,000¿ø
 
 
 
 
 
 
 
 
 
 
 
¡à °íÃâ·Â ÆÄ¿ö¿ë ¹èÅ͸®

 

¡á Primary lithium-thionyl chloride (Li-SOCl©ü) ¸®Æ¬1Â÷¹èÅ͸® High power 
 

 [ Ä¿³ØÅÍ ¿¬°áÀ» ¿øÇÏ½Ã¸é »óÇ°ºÐ·ù <Ä¿³ØÅÍ Connecter> ¿¡¼­ ¼±ÅÃÇØ ÁÖ¼¼¿ä ]



¡Þ Nominal voltage : 3.6V (Open circuit Voltage 3.67V)
 
¡Þ Nominal capacity : 13000mAh (13Ah) 

 
¡Þ Size : (D) 33.4 x 61.6mm 
 
¡Þ Weight : 100g

¡Þ Pulse capability : Typically up to 4000mA 


¡Þ Maximum recommended Continuous Current : 1800mA

 
¡Þ Operating temperature range : -60 ~+85 ¡É

 

¡Þ Storage (recommended) : + 30 ¡É Max.

           


             < ¡è ¸¶À̳ʽº(-) ±Ø >


  



1 Typical values relative to cells stored up to one year at + 30¡ÆC max. 

2 Sleeved cell. 

3 Dependent upon current drain, temperature, cut-off and cell orientation. 

4 Under 4 A / 0.1 second pulses, drained every 2 minutes at + 20¡ÆC from undischarged cells 

during 24 h, with 10 µA base current, yield voltage readings above 3.0 V after initial stabilisation. 

The readings may vary according to the pulse characteristics, the temperature, 

and the cell¡¯s previous history. 

Fitting the cell with a capacitor may be recommended in severe conditions or for high pulse currents. 

Consult Saft. 

5 Operation above ambient temperature may lead to reduced capacity and lower voltage readings. 

Consult Saft. 

6 For more severe conditions, consult Saft




            






 


 

 
 
 
 
»óÈ£¸í : (ÁÖ)°¡Áø¹èÅ͸® »ç¾÷ÀÚµî·Ï¹øÈ£ : 113-86-69750 113-86-69750 Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2013-¼­¿ï±¸·Î-0340È£
[ÀÌ¿ë¾à°ü] [°³ÀÎÁ¤º¸ 󸮹æħ] °³ÀÎÁ¤º¸ º¸È£ Ã¥ÀÓÀÚ : ¾öÇýÁø ´ëÇ¥ : ±ÇºÀ°©
»ç¾÷Àå¼ÒÀçÁö : ¼­¿ï½Ã ±¸·Î±¸ °æÀηÎ53±æ 15 ¹Ùµ¿3405È£,3406È£(±¸·Îµ¿,Áß¾ÓÀ¯Åë)
Copyright ¨Ï (ÁÖ)°¡Áø¹èÅ͸® All Rights Reserved. TEL 02-6679-3399, 010-4583-3397, FAX 02-6679-3396